¡ß Drawing Data
 
 
Dimensions & Weight
Size
4x8x2 3/8 inches (99x198x60mm)
 
Weight
2.2lbs (1,000g)
 
Physical Properties
Modulus of Rupture
8.23 N/mm©÷
(=85 kgf/cm©÷)
(ASTM C 67)
Compressive Strength
0.79 N/mm©÷
(=8.1 kgf/cm©÷)
(ASTM C 67)
Breaking Load
13.18 N
(=1,345 kgf)
(ASTM C 67)
Operating emperature
-13oF ~ 140oF (-25oC ~ 60'C)
   
Operating Time
8 hours minimum
 
Onset Point
120 Lux
 
Charging Time
1(sunny) to 8 (cloudy and rainy) hours
   
Lighting Properties
   
Model No
Color
Brightness (Nit)©ö
Illuminance(Lux)©÷
Uniformity©ø
average
min
average
min
average
min
ST-0408GL
Green
10.6
10.0
33.3
31.4
75%
80%
ST-0408BL
Blue
2.6
2.4
8.2
7.5
75%
80%
ST-0408WL
White
6.0
5.1
18.9
15.9
75%
80%
ST-0408RL
Red
5.5
4.9
17.3
15.4
75%
80%
ST-0408OL
Orange
4.7
4.2
14.8
13.2
75%
80%
ST-0408AL
Amber
2.9
2.5
9.1
7.9
75%
80%
1.Luminance (cd/m©÷) measurement: The luminance of 9 points on the lighting area 1.measured and averaged.
2.Illuminance (lm/m©÷) is obtained by multiplying 3.14 to brightness.
3.Uniformity is obtained by dividing minimum luminance by maximum luminance from 9 1.point measurement.
 
¡ßReference Standards
AASTM C902: Standard Specification for Pedestrian and Light Traffic Paving Brick
AIESNA DG-5-1994: Recommended Lighting for Walkways and Class 1 Bikeways
Walkway Class
Avg. Maintained Illuminance Levels in Lux (Horizontal Levels)
Commercial
10
Intermediate
5
Residential
2
 
¡ßIllumination Example
Place
Lux
Place
Lux
direct sunlight
100000
cloudy day
30000~70000
very cloudy day
10000~30000
rainy day
7000~10000
full moon
0.2
good illumination for reading
200~500
 
¡áEasy Installation Anywhere
 -sunlight, rain or shade
 -horizontal or vertical placement
¡áWide Operating Temperature
 -40¢µ~167¢µ (-40¡É~75¡É)

¡áAutomatic On/Off ¡áNo Electric Leakage
¡áSemi-Permanent Life
 -unlimited charge/discharge cycle
 -no degradation of energy torage no performance
¡áWater-Proof Structure

¡á
Non-Contaminating Materials
 
Thanks to its characteristics of no maintenance, long life of more than 10 years and wide operating temperature range, it can be installed anywhere. Installation itself is very easy. Different from 12V low voltage lighting requiring wiring, it can be placed anywhere you want it to be without range constraints of wire. When it is installed on the surface of garden, driveway, garden path or any place, it will not only beautify the landscape but also guide the pedestrian traffic or light vehicular traffic.